MRGlu (FDG Patlak, Slice-dependent Times)

<< Click to Display Table of Contents >>

Navigation:  PXMOD Model Reference > Models for Dynamic Whole-body Scans >

MRGlu (FDG Patlak, Slice-dependent Times)

The MRGlu (FDG Patlak, Slice-dependent Times) model is intended for the quantitative assessment of the regional metabolic rate of glucose (MRGlu) with FDG. The required measurements are a dynamic PET scan after the injection of a FDG bolus and a measurement of the FDG activity in blood. The analysis is done using the Patlak graphical plot method [1] which has been developed for systems with irreversible trapping, ie. k4=0 in a 2-tissue compartment model.  

picture_6446

However, this model structure is not necessary for the application of the method. It is sufficient to have any compartment in the system which binds irreversibly.

The Patlak plot belongs to a group of Graphical Analysis techniques, whereby the measured tissue TAC CT(T) undergoes a mathematical transformation and is plotted against some sort of "normalized time". The Patlak plot is given by the expression

Equation Patlak

with the input curve Cp(t). This means that the measured PET activity is divided by plasma activity, and plotted at a "normalized time" (integral of the input curve from the injection time divided by the instantaneous plasma activity). For systems with irreversible compartments this plot will result in a straight line after an equilibration time t*, which is dependent on the tissue properties and may range between 20 and 60 minutes.

picture_6447

The slope and the intercept must be interpreted according to the underlying compartment model. For the FDG tracer, the slope Ki equals K1k3/(k2+k3) and represents the metabolic influx, while the intercept equals V1+vB with the distribution volume V1 of FDG in tissue and the fractional blood volume vB.

For the analysis of FDG data, a Lumped Constant (LC) and the Plasma glucose level (PG) of the patient need to be entered. The metabolic rate of glucose MRGlu is then obtained from the regression slope Ki by

picture_6448

Acquisition and Data Requirements

Image Data

A dynamic PET data set representing the measurements covering a sufficient time range after injecting a 18F-Deoxy-Glucose (FDG) bolus. If the scanner FOV was not at a fixed location during the scan, the slice-times need to be contained in the image attributes. The model has been tested with the data of Siemens equipment (DICOM Conformance statement, see Frame Reference Time).

Blood Data

Blood activity from the time of injection until the end of the scan. It is important, that the blood and the image data have the same time base and decay correction is relative to the same time.  

Blood Preprocessing

The only necessary configuration is specification of the blood activity curve, either as a file, or as a VOI placed over a vessel such as the descending aorta or the left ventricle. Note, however, that the blood information must be available from the time of injection, whereas later measurements are sufficient for the tissue.

picture_9684

Note: A single exponential function is fitted to the blood data from 25 minutes. This approach is reasonable for FDG data and reduces noise in the Patlak estimation.

Model Preprocessing

The model processing panel includes two classes of options.

picture_9685

The options at the top are related to the handling of the timing, see Variable Timing of Slices. The parameters of the actual Patlak plot are:

Patlak Start Frame

Specification of t* in real acquisition time is not appropriate, because the times are slice-dependent. Therefore, the frame number is specified from which on the data in the Patlak plot is used for linear regression.

Plasma Gluc.

Plasma glucose in [mmol/l] measured with a blood sample of the patient.

Lumped Constant

The Lumped Constant is used to compensate for the difference in uptake between normal glucose and Fluoro-Deoxyglucose (FDG). It differs between tissues and therefore is set to 1 by default.

Percent masked pixels

Exclude the specified percentage of pixels based on histogram analysis of integrated signal energy. Not applied in the presence of a defined mask.

Model Configuration

picture_9686

MRGlu

Metabolic Rate of Glucose in [μmol/min/100ml], the actual result of the model. It is calculated as:
MRGlu = Slope*Plasma_Glucose/Lumped_Constant.

Ki

Slope of the linear regression. It equals the influx Ki=(K1*k3)/(k2+k3) of the 2-tissue compartment model and is directly proportional to MRGlu.

DV

Distribution volume of FDG in tissue plus blood fraction (= intercept of the linear regression).

Reference:

1.Patlak CS, Blasberg RG, Fenstermacher JD: Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 1983, 3(1):1-7. DOI