Fitting Problems

<< Click to Display Table of Contents >>

Navigation:  PKIN Data Processing > Configuration and Fitting of Kinetic Tissue Models > Kinetic Model Fitting >

Fitting Problems

In the case of a failed fit it is worthwhile to check the console output. For example, the output text reproduced below clearly indicates that the 4th fit parameter caused a problem.

Singular Matrix-2
covar[1][1] = 2.1652603147908747E-6
covar[1][2] = -5.120936302955895E-4
covar[1][3] = 2.862241687078937E-7
covar[1][4] = 0.0
covar[2][1] = -5.120936302955895E-4
covar[2][2] = 0.3918087002588389
covar[2][3] = -2.0406232308544742E-4
covar[2][4] = 0.0
covar[3][1] = 2.862241687078937E-7
covar[3][2] = -2.0406232308544742E-4
covar[3][3] = 1.4044964781403112E-7
covar[3][4] = 0.0
covar[4][1] = 0.0
covar[4][2] = 0.0
covar[4][3] = 0.0
covar[4][4] = 0.0

Such problems might be caused by initial values very close to parameter restrictions.