Deformable Matching (SPM5)

After the appropriate template has been loaded as the Reference and the study to be spatially normalized as the Reslice, activate the Deformable Matching (SPM5) button. A dialog window appears for configuring the processing.

The Deformable Matching (SPM5) button provides access to the different types of elastic matching methods. An interface dialog window appears with two tabs. The first one serves to quickly retrieve species sensitive pre-defined or saved configurations of the iterative matching settings, the second one gives access to all parameters.

clip0015

There are buttons in the Method pane to establish proper parameter presets for certain tasks, particularly for processing HUMAN,RAT or MOUSE data. Activating one of the buttons displays the Normalization Parameters pane with appropriately configured settings. The Last used button restores the parameter configuration of the latest Deformable Matching invocation, and the list selection allows retrieving special purpose parameter sets.  

There are Basic and Advanced parameters on separate tabs.

picture_5009

The settings available in the panels allow fine-tuning the basic procedure.

Basic Parameters

Smooth template,
Smooth input

If either box is checked, an initial Gaussian smoothing of the respective data is performed. Both smoothing operations use the same configurable parameters. Usually, the atlas has already been smoothed beforehand so its smoothing is not required for the normalization.

Sampling rate

The sampling rate of the method is derived from the Smooth Input filter size. If no smoothing is applied, the sampling rate needs to be specified by the user.

Template Mask

This section is needed for defining a mask to be applied during the normalization procedure. In this case, you need to select a file corresponding to the template which restricts normalization to the meaningful area.

To discard the mask activate the Clear file or directory button PFUS Discard Mask

Input Mask

This option allows defining a mask to be applied during the normalization procedure. You need to select a file corresponding to the Input image which restricts normalization to the meaningful area.

To discard the mask activate the Clear file or directory button PFUS Discard Mask

Resulting bounding box

The radio box selection allows defining the extent (bounding box) of the resulting normalized images.

Full template: the result image has the size of the used template.

Talairach: the result image is trimmed to the bounding box of the Talairach brain atlas as in the SPM programs.

Advanced Parameters

The Advanced parameters are usually only changed if a normalization fails or if the user aims at a specific effect.

picture_5010

Image thresholding

The image volume considered during matching can be restricted to a sub-volume by thresholding, eg. by excluding the image background.

Absolute values can be defined when User defined option is selected as thresholding method.

Nonlinear warping

If this box is not checked, only the affine (translation, rotation, scaling, shearing) part of the normalization is performed.

Iterations

Number of nonlinear iterations. The higher the iterations number, the more deformations may occur.

Frequency cutoff

The specified Frequency cutoff (default = 25) is used together with the Bounding box size to calculate the number of basis functions. Higher cutoff values result in fewer basis functions.

Affine step

Estimate and apply an affine transformation before the nonlinear warping iterations start

SPM/MNI/ICBM altas

Use settings which are appropriate for the templates of these standard atlases.

Starting the Normalization

The Normalize Current button (or Normalize if only one Reslice series was loaded) starts the normalization process of the current Reslice series with the given settings. A bar will appear in the status line which indicates the normalization progress. With Normalize All all Reslice series are sequentially normalized.