Table Layout

<< Click to Display Table of Contents >>

Navigation:  R Statistics in PMOD >

Table Layout

Variable Selection

The picture_6703 button activates the Table layout for inspecting the data in the R workspace. The R variables can be selected from the Preview list indicated below.  

picture_6712

The list will show the original variables as well as variables created by the scripts and R commands.

Table View Layout

After selecting a variable, its content can be inspected. The default 2D view illustrated below shows the table of the data frame.

RExeTableInterface

The lower plot area shows scatter plots of a data Row or Column. One variable may have different data frames for different aggregated outcome statistics such as avr, hav, and med. The Statistics selection can be used to change between statistics, as well as direct double-clicking into the Statistics list.

picture_6830

In order to keep track of the variable meaning, comments can be added in the lower right. Please select the variable of interest, enter the comment, and then activate the copy button illustrated below. When saving the R workspace, this comment will be included, so that it will be available when resuming work.

picture_6831

Table Buffer

Note that each visualization of a table is stored in a buffer list so that it can be quickly recalled. While a variable exists only once, there might be multiple entries in the buffer which may represent the visualization of different variable parts.

picture_6832

The buffer list can be edited with the buttons to its right:

Button Remove from selected

Remove current table from the list.

picture_7871

Save all tables into a file.

RCommandToolbar_CopyButton

Copy the current table to the clipboard.

Button Remove all from selected

Clear the buffer list.

Surface Plot Visualization (Option)

The tables from the buffer can also be visualized as 3D surfaces as illustrated below.

picture_6833

It is essential, that before enabling this display the buffer is prepared so that only meaningful tables remain. Please remove the other tables with the x button. For information about the 3D rendering please refer to the PMOD 3D Rendering User's Guide.

3D Visualization (Option)

When the 3D radio button is enabled, the selected buffer table is displayed as shown below.

picture_6835

Dynamic Data

If the loaded statistic has a time dimension, the table represents the values at a certain time which can be selected in the TIME VECTOR list or by moving the Sample slider.

picture_6836

The TAC corresponding to the selected cell (subject/VOI) and the selected Statistics is plotted in the Vector tab, and all TACs in the All tab.